"Désignation","Description","code article","Stroke [mm]","Push Force [N]","Pull Force [N]","Speed No Load [mm/s]","Speed Full Load [mm/s]","IP protection class","Motor voltage [V]","Current consumption [A]","Ambient temperature [°C]","Bending load[Nm]","Bending moment (dynamic) [Nm]","Current push [A]","Current pull [A]","Cable /connecting plug","Cable options","Dynamic bending moment [Nm]","Duty cycle: intermittent min","Duty cycle (on/off)","Electrical options","Input current [A]","LAN cable through","Motor orientation","Noise level (max) [dB]","Operating device rotation","Option","Power [W]","Retracted Lengtt (L1) [mm]","Static load (push) [N]","Static factor on rated load","Switching function [normally closed/normally open]","Static bending moment (max) [Nm]","Stand by power [W]","Type","Telescopic pillar version [#]","Weight [kg]","Type of control"
"TLG10-AD24F-000","Colonne téléscopique Telemag TLG","M/0120366","200","4000","0","10-14","24 DC"," 30","","6.5","+10 to +40","up to 2800","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-AD34F-000","Colonne téléscopique Telemag TLG","M/0121608","300","4000","0","10-14","24 DC"," 30","","6.5","+10 to +40","up to 2800","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-AD44F-000","Colonne téléscopique Telemag TLG","M/0122036","400","4000","0","10-14","24 DC"," 30","","6.5","+10 to +40","up to 2800","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-AD54F-000","Colonne téléscopique Telemag TLG","M/0129977","500","4000","0","10-14","24 DC"," 30","","6.5","+10 to +40","up to 2800","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-AD74F-000","Colonne téléscopique Telemag TLG","M/0120962","700","4000","0","10-14","24 DC"," 30","","6.5","+10 to +40","up to 2800","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-CD34F-000","Colonne téléscopique Telemag TLG","M/0128198","300","1500","0","25-33","24 DC"," 30","","6.5","+10 to +40","up to 950","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLG10-CD74F-000","Colonne téléscopique Telemag TLG","M/0129864","700","1500","0","25-33","24 DC"," 30","","6.5","+10 to +40","up to 950","","","","","","","1 min./9 min.","","","","","","","","","156","S+180","","","","","","","3-section","",""
"TLT10-A134F-000","Colonne téléscopique Telemag TLT","M/0128082","300","3000","0","11-16","24 DC"," 40","","2x3.5","+10 to +40","up to 400","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+170","","","","","","","3-section","",""
"TLT10-A144F-000","Colonne téléscopique Telemag TLT","M/0122459","400","3000","0","11-16","24 DC"," 40","","2x3.5","+10 to +40","up to 400","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+170","","","","","","","3-section","",""
"TLT10-A164F-000","Colonne téléscopique Telemag TLT","M/0128485","600","3000","0","11-16","24 DC"," 40","","2x3.5","+10 to +40","up to 400","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+170","","","","","","","3-section","",""
"TLT10-A174F-000","Colonne téléscopique Telemag TLT","M/0120361","700","3000","0","11-16","24 DC"," 40","","2x3.5","+10 to +40","up to 400","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+170","","","","","","","3-section","",""
"TLT10-A234F-000","Colonne téléscopique Telemag TLT","M/0121306","300","4000","0","13-19","24 DC"," 40","","2x3.5","+10 to +40","up to 1000","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+240","","","","","","","3-section","",""
"TLT10-A244F-000","Colonne téléscopique Telemag TLT","M/0120414","400","4000","0","13-19","24 DC"," 40","","2x3.5","+10 to +40","up to 1000","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+240","","","","","","","3-section","",""
"TLT10-A254F-000","Colonne téléscopique Telemag TLT","M/0129425","500","4000","0","13-19","24 DC"," 40","","2x3.5","+10 to +40","up to 1000","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+240","","","","","","","3-section","",""
"TLT10-A264F-000","Colonne téléscopique Telemag TLT","M/0122283","600","4000","0","13-19","24 DC"," 40","","2x3.5","+10 to +40","up to 1000","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+240","","","","","","","3-section","",""
"TLT10-A274F-000","Colonne téléscopique Telemag TLT","M/0122129","700","4000","0","13-19","24 DC"," 40","","2x3.5","+10 to +40","up to 1000","","","","","","","1 min./9 min.","","","","","","","","","168","0.5 x S+240","","","","","","","3-section","",""
"TLT10-C234F-000","Colonne téléscopique Telemag TLT","M/0121465","300","2000","0","25-42","24 DC"," 40","","2x4.5","+10 to +40","up to 480","","","","","","","1 min./9 min.","","","","","","","","","216","0.5 x S+240","","","","","","","3-section","",""
"TLT10-C244F-000","Colonne téléscopique Telemag TLT","M/0127081","400","2000","0","25-42","24 DC"," 40","","2x4.5","+10 to +40","up to 480","","","","","","","1 min./9 min.","","","","","","","","","216","0.5 x S+240","","","","","","","3-section","",""
"TLT10-C264F-000","Colonne téléscopique Telemag TLT","M/0128512","600","2000","0","25-42","24 DC"," 40","","2x4.5","+10 to +40","up to 480","","","","","","","1 min./9 min.","","","","","","","","","216","0.5 x S+240","","","","","","","3-section","",""
"TLT10-C274F-000","Colonne téléscopique Telemag TLT","M/0129385","700","2000","0","25-42","24 DC"," 40","","2x4.5","+10 to +40","up to 480","","","","","","","1 min./9 min.","","","","","","","","","216","0.5 x S+240","","","","","","","3-section","",""
"CPMT1-1M0300F2-000","Colonne téléscopique pour procédure médicale","M/0131091","300","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 1200","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-1M0400F2-000","Colonne téléscopique pour procédure médicale","M/0131102","400","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 1200","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-1M0500F2-000","Colonne téléscopique pour procédure médicale","M/0131138","500","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 1200","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-1M0600F2-000","Colonne téléscopique pour procédure médicale","M/0131083","600","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 1200","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-1S0500F2-000","Colonne téléscopique pour procédure médicale","M/0131136","500","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 450","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMT1-1S0550F2-000","Colonne téléscopique pour procédure médicale","M/0131148","550","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 450","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMT1-1S0600F2-000","Colonne téléscopique pour procédure médicale","M/0131038","600","5000","4000","14 - 34","","20","24 - 30","","+10 to +40","","","12","10","","2.3 m DIN8 cable","up to 450","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMT1-2M0300F2-000","Colonne téléscopique pour procédure médicale","M/0131092","300","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 1400","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-2M0400F2-000","Colonne téléscopique pour procédure médicale","M/0131103","400","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 1400","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-2M0450F2-000","Colonne téléscopique pour procédure médicale","M/0131127","450","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 1400","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-2M0500F2-000","Colonne téléscopique pour procédure médicale","M/0131139","500","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 1400","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-2M0600F2-000","Colonne téléscopique pour procédure médicale","M/0131084","600","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 1400","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 240 mm","15000","4","","3000","","","","19 - 23.5",""
"CPMT1-2S0400F2-000","Colonne téléscopique pour procédure médicale","M/0131042","400","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 550","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMT1-2S0500F2-000","Colonne téléscopique pour procédure médicale","M/0131137","500","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 550","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMT1-2S0550F2-000","Colonne téléscopique pour procédure médicale","M/0131149","550","6000","4000","12 - 26","","20","24 - 30","","+10 to +40","","","10","7","","2.3 m DIN8 cable","up to 550","","1 min./9 min.","2-Hall encoder, end limit switches","","","","","","","","stroke/2 + 120 mm","15000","4","","1000","","","","16.5 - 20",""
"CPMA1-12230AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0130633","230","1000","0","14 - 15","","I","100–240 AC 50/60 Hz","","+10 to +40","","up to 115","","","","","","1 min./9 min.","","","1.5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","1 - 2.1","20","2-section","8 - 11","electrical"
"CPMA1-12250AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0130634","250","1000","0","14 - 15","","I","100–240 AC 50/60 Hz","","+10 to +40","","up to 115","","","","","","1 min./9 min.","","","1.5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","1 - 2.1","20","2-section","8 - 11","electrical"
"CPMA1-12300AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0130180","300","1000","0","14 - 15","","I","100–240 AC 50/60 Hz","","+10 to +40","","up to 115","","","","","","1 min./9 min.","","","1.5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","1 - 2.1","20","2-section","8 - 11","electrical"
"CPMA1-12400AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0130351","400","1000","0","14 - 15","","I","100–240 AC 50/60 Hz","","+10 to +40","","up to 115","","","","","","1 min./9 min.","","","1.5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","1 - 2.1","20","2-section","8 - 11","electrical"
"CPMA2-22200AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0131604","200","2000","0","11 - 15","","","24 DC","","+10 to +40","","up to 250","","","","","","1 min./9 min.","","","5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","","20","2-section","8 - 11","electrical"
"CPMA2-22250AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0131616","250","2000","0","11 - 15","","","24 DC","","+10 to +40","","up to 250","","","","","","1 min./9 min.","","","5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","","20","2-section","8 - 11","electrical"
"CPMA2-22300AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0131325","300","2000","0","11 - 15","","","24 DC","","+10 to +40","","up to 250","","","","","","1 min./9 min.","","","5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","","20","2-section","8 - 11","electrical"
"CPMA2-22400AA0-000","Colonne téléscopique pour équipement ophtalmologique","M/0131627","400","2000","0","11 - 15","","","24 DC","","+10 to +40","","up to 250","","","","","","1 min./9 min.","","","5","No","Motor in inner tube","45","Operating device socket as the motor ","","","S+160","","","8000","500","","20","2-section","8 - 11","electrical"
"TLG10-AA24F-000","Colonne téléscopique Telemag TLG","M/0121702","200","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 2,3 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"
"TLG10-AA33F-000","Colonne téléscopique Telemag TLG","M/0129444","300","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 1,0 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"
"TLG10-AA34F-000","Colonne téléscopique Telemag TLG","M/0121576","300","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 2,3 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"
"TLG10-AA44F-000","Colonne téléscopique Telemag TLG","M/0121579","400","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 2,3 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"
"TLG10-AA54F-000","Colonne téléscopique Telemag TLG","M/0122035","500","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 2,3 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"
"TLG10-AA74F-000","Colonne téléscopique Telemag TLG","M/0128397","700","4000","0","10-14","","SELV","24 DC","6.5","+10 to +40","up to 2800","","","","Straight, 2,3 m / DIN8 plug","","","1 min./9 min.","","","","","","","","2-Hall encoder, cable with DIN8 plug","156","S+180","","","","","","30","2-section","15 - 30","electrical"